Likes Likes:  0
Resultaten 1 tot 2 van de 2
Geen
  1. #1
    nolimit bugtraq
    Bay Technical Associates telnet server logon bypass
    Gast
    n/a Berichten
    Berichten zijn liked



    Thread Starter

    Bay Technical Associates telnet server logon bypass

    Vulnerability found by Flare@CiSO
    Greets to nolimit, COREiSO, #news, and class101.

    Versions Tested:
    RPC-3 Telnet Host - Revision F 3.05, (C) 1998

    This is a basic login-bypass vulnerability found in the RPC-3 Telnet
    Host v 3.05 made by "Bay Technical Associates". This telnet daemon is
    used by many hardware appliances, often times power supplies. When a
    user logs into this telnet daemon they are able to gain full control
    of the device (in this example a power supply). We consider this
    vulnerability an extreme risk as it could allow an unauthorized user
    to login to a power supply, and disable power to a machine, thereby
    completely shutting down and disabling the aforementioned machine (or
    anything else connected to such a power supply).

    To carry out this exploit an attacker simply needs to telnet to the
    RPC-3 Telnet daemon on the standard telnet port, and when prompted for
    the username hit the escape key, and then enter. The attacker will
    then be logged into the Telnet Daemon.

    This attack was tested on RPC-3 Telnet Host version 3.05. Other
    versions were not available for testing; they may or may not prove to
    have the same vulnerability.

    Example:

    RPC-3 Telnet Host
    Revision F 3.05, (C) 1998
    Bay Technical Associates
    Unit ID: RPC3

    Enter username> [escape key] [enter]
    Login successful.

    Available RPC3 Outlets
    For command summary, enter HELP

    Circuit Breaker: On

    Selection Outlet Outlet Power
    Number Name Number Status

    RPC3> [attacker now has control of the appliance]

  2. #2
    Michael Brennen
    Bay Technical Associates telnet server logon bypass
    Gast
    n/a Berichten
    Berichten zijn liked



    Thread Starter

    Re: Bay Technical Associates telnet server logon bypass

    On Thu, 31 Mar 2005, nolimit bugtraq wrote:

    > Versions Tested:
    > RPC-3 Telnet Host - Revision F 3.05, (C) 1998
    >
    > This is a basic login-bypass vulnerability found in the RPC-3 Telnet
    > Host v 3.05 made by "Bay Technical Associates". This telnet daemon is
    > used by many hardware appliances, often times power supplies. When a
    > user logs into this telnet daemon they are able to gain full control
    > of the device (in this example a power supply). We consider this
    > vulnerability an extreme risk as it could allow an unauthorized user
    > to login to a power supply, and disable power to a machine, thereby
    > completely shutting down and disabling the aforementioned machine (or
    > anything else connected to such a power supply).
    >
    > To carry out this exploit an attacker simply needs to telnet to the
    > RPC-3 Telnet daemon on the standard telnet port, and when prompted for
    > the username hit the escape key, and then enter. The attacker will
    > then be logged into the Telnet Daemon.
    >
    > This attack was tested on RPC-3 Telnet Host version 3.05. Other
    > versions were not available for testing; they may or may not prove to
    > have the same vulnerability.


    RPC-3 Telnet Host Revision F5.10.4 is not vulnerable to this
    particular sequence. I have no idea about other revisions.

    Michael Brennen
    President, FishNet(R), Inc.
    Professional Internet Services


Webhostingtalk.nl